Error in installing HP Insight Management WBEM Providers for Windows Server ?

Hi Folks, Where can I find the error log to see the detailed error message when installing the WBEM providers on Windows Server 2008 R2 ? The installation procedure did not complete successfully. An...

View Article


HP Blade ILO4 using only SNMP V3, Traps not received in HP SIM

Hi Xeon, Can you please tell me how you configured SNMP V3 in HP blade center C7000.

View Article


Error in testing WMI ?

Hi All, Can anyone please let me know what to expect or to verufy when performing the Test WMI ?because I only get the following result for all options on the newly installed WBEM provider: [See...

View Article

Re: Which one to use HP SIM or HP Insight System Notifier for server hardware...

Hello again, Yes you are correct, WBEM is the least work and the savest since SNMP is V1 SNMP and this an be sniffed easily from your network . Only devices like switches ect should and can only use...

View Article

Re: CIMNOTIFY service fails

Yes you can run a repair job to you selected servers. To run this select the servers,go to Configure > Configure or Repair Agent frum the menu, in the first screen you can select any extra servers,...

View Article


Re: No Event entries after upgrading to v7.4 (plus DB migration to SQL2012)

Do the events get handled in the Trap folder or does it keep growing ?? 

View Article

Re: No Event entries after upgrading to v7.4 (plus DB migration to SQL2012)

Hello. The event are handled in the trap folders and are deleted instantly. If I am monitoring the traps folder, I see that the server recieves the traps, but the CMS does not generate any events and...

View Article

Re: VCRM invalid or not reachable from all VCA's

Worked for me, too.   THANKS!!

View Article


Re: Error in installing HP Insight Management WBEM Providers for Windows...

You do have admin rights on these servers ? and are these set for your servers ?Are the SIM and the SIm server separated by a firewall ?

View Article


Re: No Event entries after upgrading to v7.4 (plus DB migration to SQL2012)

Hello, Could be a database problem use the build-in database repair tool in SIM  called mxconfigrepo -c for check and option -f for fixing database problems.

View Article

Re: Error in testing WMI ?

Did you set a subscription for where the server should send the events to? Should be the SIM server. This can be done from SIM. You need write rights in the WMI stack, a local admin should be more...

View Article

Re: Error in testing WMI ?

Hi Andrew,My login to the server is local administrator and domain admins.There is no configured SIM server yet.I don't know where to configure the subscription.

View Article

Re: HP Insight Foundation Agents - service stopping (Windows 2003)

Just checked the ntdll.dll thing and it's the same on both the working and non-working servers. I know it's been years since anyone posted on this issue but I'm still plugging away on this for one of...

View Article


Re: Error in testing WMI ?

Hello,There are two methodes, both done from the SIM interface. You can choose your systems that your to set the subscription for and then select Configure > Repair option from the menu. The first...

View Article

Re: HP Insight Foundation Agents - service stopping (Windows 2003)

What is the hardware and OS platform? You can update the management agent seperatly from the other packages. If it's 2003 the agents from PSP 8.70 should still work.

View Article


Re: VCRM invalid or not reachable from all VCA's

I had the same issue - when copying and pasting from this webpage it adds a sneeky question mark before RC4, just delete that and it will run. Didn't fix my problem though - still have some servers...

View Article

Re: Windows 2012 R2 discovery issue by SIM

Hello there, if you have SIM questions you should ask your questions here :http://h30499.www3.hp.com/t5/ITRC-HP-Systems-Insight-Manager/bd-p/itrc-455 But your question, is SNMP configured on the server...

View Article


Re: Windows 2012 R2 discovery issue by SIM

Sorry for posting in the wrong area. Yes. I have configured SNMP on the host already. In fact, this problem also existed on Windows 2012. The reason I used SNMP is that sometimes I don't necessarily...

View Article

Re: Windows 2012 R2 discovery issue by SIM

Can you run a Identify of a sample server you want to monitoring/scan. Please paste the log this identify gives in this forum. That should give us a hint wheat goes wrong. You can always disable the...

View Article

Re: No Event entries after upgrading to v7.4 (plus DB migration to SQL2012)

Hello. mxconfigrepo -f fixed some errors, but anyway the problem still exists :/

View Article