Re: VCRM no longer found in SIM
If i look at the log i see that SNMP works but nu Hp SNMP management agents installed. You could install these or add Windows credentials for the WBEM Discovery.
View ArticleRe: How to setup HP SIM alerting to email different team for different IP...
For this to work you need to create collections for the group of servers you want to send email to a group. Do you know how to create a collection of servers?
View ArticleRe: No event on PS failure??!
Thank you again, Andrew. That didn't seem to work. I change the severity to Critical but it still shows up as an informational event. I've been reading thru a few other spearate posts here, a...
View ArticleRe: No event on PS failure??!
I've had a lot of problems with WBEM events for ESX servers do i switched to SNMP trough the ILO. Don't you get the event from the ILO then?
View ArticleRe: Systems Management Home Page shows No Items
We have faced similar issue, following will fix the the issue. 1. Ensure that the SNMP service is Enabled 2. Reinstall HP Insight Management Agents...
View ArticleRe: How to setup HP SIM alerting to email different team for different IP...
Unfortuantely no I don't know where to create it from ? after that do I just select the servers based on the filter criteria ?
View ArticleRe: HP SIM error Could not set the disk threshold, the agent did not accept...
Thanks for the guide Andrew, so does this can cause unwanted outage or not affecting the production server ?
View ArticleRe: How does HP SIM works in Enterprise Data Center and multiple IP subnets ?
Thanks Andrew, So yes, the option to centrally configure the bulk majority / selected servers SNMP to point / send the data to HP SIM server can be found in the Configure or Repair Agentsand then on...
View ArticleRe: VCRM no longer found in SIM
SNMP agents don't install on a VM, I thought? Also, I didn't need them when VCRM was running on Windows 2008R2.
View ArticleRe: VCRM no longer found in SIM
Right, it's a virtual, can you add the WBEM/WMI credentials then ? SIM needs to know it's a server so it will run the SMH discovery
View ArticleRe: How does HP SIM works in Enterprise Data Center and multiple IP subnets ?
Hello Albert, On step 3: Create subscriptions to WBEM events Configure SNMP Trap Community string public. I would expect that the SNMP read was alreay set, if not also select that one. Deselect the...
View ArticleRe: HP SIM error Could not set the disk threshold, the agent did not accept...
Hello, This is the screen for installing an agent, this should not have any effect for your operations. It's possible that you need to reboot to make the changes active. So don't select the option to...
View ArticleRe: VCRM no longer found in SIM
I've added the account that has admin rights on the server (and which is used to run the pegasus WMI mapper service) is added to both the Global credentials and the system credentials. I've checked...
View ArticleRe: How to setup HP SIM alerting to email different team for different IP...
Hello, When you are in SIM look at the left side of he screen under the Search bar. There you see Customize in blue, click this link. Now you get a screen where you can edit existing collections or...
View ArticleRe: How to setup HP SIM alerting to email different team for different IP...
To have your servers automatically be added to a collection use the contact string or location strings under snmp on the monitored servers and have your collections criteria in SIM sort on that. I...
View ArticleRe: How to setup HP SIM alerting to email different team for different IP...
Attached is what two of my collection setups look like. The servers in alarm collection is very usefull. As servers go into/out of alarm they show up and dissapear from the collection. With that...
View ArticleRe: How to setup HP SIM alerting to email different team for different IP...
I must say that is a good option certainly if you have a lot of servers and a dynamic number of them. You could use the repair option in SIM or any other tool that can run scripts to adapt your SNMP...
View ArticleHP SIM and ESXi
Hi, I installed HP SIM couple of week ago with the idea of having a patch solution for our ESXi environment (install software & firmware but i cant get it to do what i need.The installation should...
View ArticleRe: HP SIM and ESXi
Hello, You could start HPSUM, that's what you use and run it from a Windows or Unix server and scan the ESX server remote. Perhaps this will give more info. If i where you i would focus on HPSUM and...