Re: HP SIM show unknow cluster error G7
Hello,Yes you should leave the settings on WBEM as this is the best supported protocol for Windows servers, i just meant that if you have SNMP agents installed they could be the cause of your error. So...
View ArticleMissing information on hp sim
Dears,I installed the latest hp sim 7.4 on Linux server and monitored multiple G8 servers over ilo and snmp.I got CPU information from only one server. I got nothing from others. Even I put the same...
View ArticleConsolidating Server hardware event to be reported by HP SIM and send out...
Hi All, I'd like to achieve these tasks but not sure if it is possible or not: 1. When there is hardware fault or event status change, alert once from HP SIM only so not to double the email alert from...
View ArticleRe: Missing information on hp sim
Hello,For Gen8 or newer you need to monitor and collect software and firmware information by configuring the ILO and AMS (Agentless Management service) you need to set the SNMP config to any read...
View ArticleRe: Missing information on hp sim
In addition, don't forget to set the send hostname instead of ILO name if you want your traps to attach to the host instead of the ILO.
View ArticleRe: Consolidating Server hardware event to be reported by HP SIM and send out...
Hello,To the best of my knowledge, the event get triggered by Reading the servers status, so if an agent or server gets restarted you will get the event.The second, this is not a report but an email...
View ArticleHP SIM error Could not set the disk threshold, the agent did not accept the...
Hi, I've created the scheduled task to set the disk threshold every 6 hours so that I can get alert when the disk space usage is 90% full. But somehow when I run now with the DOMAIN\Administrator...
View ArticleHow does HP SIM works in Enterprise Data Center and multiple IP subnets ?
People, I'm still trialling HP SIM here as the means to centralized hardware monitoring for all HP products (Printers, HP Procurve Switches and HP Proliant servers). But I'm still struggling to control...
View ArticleRe: HP SIM show unknow cluster error G7
Hello,You would need credentials on the cluster so it can read the cluster service. With these rights you can rescan the nodes and you will get the cluster information. Perhaps then you can see what...
View ArticleRe: Smart Update Manager 7.2.0 hung in Scouting
Hello,This is the HP SIM forum, i think you should try the Proliant forum for SUM questions.You can find it here : http://h30499.www3.hp.com/t5/ProLiant-Servers-ML-DL-SL/bd-p/itrc-264
View ArticleRe: Smart Update Manager 7.2.0 hung in Scouting
Andrew, I've since opened a support ticket when SUM started crashing.But thanks for the pointer, I might post the result there. Sean
View ArticleRe: How does HP SIM works in Enterprise Data Center and multiple IP subnets ?
Hello,SIM uses pull actions to update status of objects already in SIM and for datacollection purposes. So no event should come from pulling unless it's a SIM alert that there was a time-out.Push...
View ArticleRe: HP SIM error Could not set the disk threshold, the agent did not accept...
Hello,Servers that have WBEM working should only use WBEM and not both, treshholds should be a one time thing. The SNMP and WBEM traps should give you the events you want. Did you set SNMP traps and...
View ArticleRe: HP SIM error Could not set the disk threshold, the agent did not accept...
Hi Andrew, where about can I see that information ? is it from the Server SMH page or the HP SIM option somewhere hiden ?
View ArticleRe: How does HP SIM works in Enterprise Data Center and multiple IP subnets ?
Here's the sample: Subject:PRODSVR2012R2-01: (SNMP) APC UPS: Communication failure: Server Critical Alerts Event Identification and DetailsEvent Severity CriticalCleared StatusNot clearedEvent...
View ArticleRe: HP SIM error Could not set the disk threshold, the agent did not accept...
Hello Albert,With SNMP it's the easiest, look at your snmp service settings in Windows, there is a tab called traps. There should be a community and your SIM server should be listed as a destination....
View ArticleRe: HP SIM error Could not set the disk threshold, the agent did not accept...
Hi Andrew,For all of my Proliant servers I only install the HP agents and WBEM and also enabling the SNMP feature.There is no further configuration on the servers to point to the HP SIM server at...
View ArticleRe: HP SIM error Could not set the disk threshold, the agent did not accept...
So that's your problem then right? If you run a repair for your servers from the configure menu. The option is Configure or repair agents. You need a windows admin account for this. Set the set webrm...
View ArticleRe: Missing information on hp sim
Andrew, When you say about configuring SNMP, out of interest do you mean in the O/S or do you mean in the ILO? Or is it both?
View Article