Re: SIM 7.4 - problem with alerts on Physical Drive Status Change

$
0
0

smamm,

 

Please see this thread, it may help:  http://h30499.www3.hp.com/t5/ITRC-HP-Systems-Insight-Manager/change-the-severity-of-an-event-in-HP-SIM-7-4/td-p/6680762#.VK6c63tlyYs

 

As a workaround for storage/"status change" events, you may want to set up a specific condition or collection to send you all non-informational events for these.  Basically, without reading the thread I linked, these are special events where you cannot change the underlying severity.  For example, a predictive failure may always be a warning, however it is the same event ID # used for a failure condition, which would be critical (event 3046).  There are a few of these types.. another would be the status for RAID cache batteries. 

 

A further example:

 

HDD failure = failure code 7, event ID 3046 - Status change for a physical drive (critical)

HDD PFA = failure code 9, event ID 3046 - Status change for a physical drive (warning)

HDD online = failure code 0, event ID 3046 - Status change for a physical drive (informational)

 

These are not the correct failure codes, but you get the idea here..  it's all the same event number.  I am not an SNMP/MIB expert so I can't fully explain this behavior, I just know you cannot change the code behavior in SIM.

 

Hope this helps!

 

 

 

 

 

 