Re: 1785 Drive Array Not Configurer - How to Not receive the alert on a server

0
0

So you clear the IML and then it becomes green, after a reboot the status is Yellow again ?


Re: HP SIM upgrade to 7.4 errors

0
0

The hotfix i mentioned was just to point out if you run these the MIBS get updated. If i read the problems with the 7.4 version i hope there will be either a new version or a hotfix. At this moment i don't see any fix.

Re: 1785 Drive Array Not Configurer - How to Not receive the alert on a server

0
0

hi

 

i'll give you an update on Monday after restart


Regards

Re: HP-SIM 7.3->7.4 Upgrade installation fails with SQL Server error

0
0

I could be wrong here, but if i remember correctly, each SIM update includes a MIB update so there is a chance the upgrade will reset anything you've changed as far as severities, filtering, etc.  Basically, the MIB file is replaced/updated and imported again so I believe the changes are lost.

 

I only mention this in case this was your main reason for not trying a clean install - in other words, it may not matter.

 

I recently upgraded to 7.4 but haven't checked to see what got reset just yet as mine isn't in full production.

 

 

Re: Problems with HP SIM 7.3 and iLo agentless monitoring

0
0

I get these as well, but since they are informational, I just ignore them.  I only send emails/alerts on major/critical and some warning conditions for drive arrays, so they are basically hidden unless someone looks at the server's event table specifically.

 

Re: SNMP outbound broken after 7.2 upgrade

0
0

Brian,

 

L3 support claims this issue was fixed in 7.3, but there are a lot of customers that cannot upgrade their 7.2.2 instance due to its reliance on Insight Remote Support Advanced 5.80 for legacy hardware.

 

I can confirm everything works just fine in 7.3/7.4 as I set up a second CMS for Gen8+ modules, but my 7.2.2 is still broken.  I have a virual room meeting scheduled for next week with L3 to look into this.  If anything comes out of it, I will continue the updates here.  My case has been open since APRIL.

 

 

 

Re: SIM Alerts

0
0

Have you set up any event handlers for the alerts?

 

The alert/event collections will show you what is happening in your envirnoment, but if you have not set up any actions on them, you will not get any emails/etc by default.  You must set up event handlers to "do something" under certain conditions.

 

For example, you can create a handler that only looks at your major and critical events and tell it to send you an email.  My setup is a little complex because I have event collections that match specific system collections that I set up (one for Windows on HP servers, one for ESXi on HP servers, and another with Windows on Dell servers).  Then my event collections only show specific events that match those system collections.  In those collections, is set up event handlers to send OM messages into Operations Manager and emails to me.  This allows me a lot of control over what events have actions and it's worked well for me, for many years.

 

Look for event handlers in the systems guide and it should help you out.

 

Re: HP-SIM 7.3->7.4 Upgrade installation fails with SQL Server error


Re: SNMP outbound broken after 7.2 upgrade

0
0

Hello Gentile,

 

Is your 7.4 setup connected to a remote SQL or local if **bleep**'s remote is it a SQL 2012 ?

 

Re: HP SIM on Windows Server 2012 R2 Essentials

Re: HP SIM on Windows Server 2012 R2 Essentials

0
0

In the meanwile HP released the 7.4 version. You could try that version. I don't see the Essentials in the specs as supported. But then again you could give it a try. 

Re: HP SIM on Windows Server 2012 R2 Essentials

0
0

thanks, but that dosnt work either stil the same error

Offline firmware upgrade via iLO without using SPP, is it possible?

0
0

Hello,

 

Does anyone know whether HPSIM can perform offline firmware upgrade without using SPP?

 

I know HPSIM can perform offline SPP deployment via Gen8 iLO device.

However, I would like to perform offline upgrade specific version of firmware, not entire SPP.

 

I created a custom software baseline in VCRM, but it does not show me "offline" upgrade option.

 

InstallSoftwareAndFirmwareOptions.png

 

Please advise if you know how to solve this problem.

 

Thanks,

Re: 1785 Drive Array Not Configurer - How to Not receive the alert on a server

0
0

Hi

 

Server restart this week end so i received an email fro mHPSIM and an Event 

 

Event Name: (SNMP) POST Errors Occurred (6027)

URL: https://xxx.xxxx.xxxx..xxxx2381/

Event originator: xxxxxx

Event Severity: Minor

Event received: 26-Oct-2014, 00:24:38

 

Event description: One or more POST errors occurred.  Power On Self-Test (POST) errors occur during the server restart process. Details of the POST error messages can  be found in Integrated Management Log

 

 

Health status is green

 

So the pb is .. how to not receive this event drom tis particular server ?


Regards

Re: 1785 Drive Array Not Configurer - How to Not receive the alert on a server


Re: Offline firmware upgrade via iLO without using SPP, is it possible?

Re: HP SIM on Windows Server 2012 R2 Essentials

0
0

WHello again,

 

i've read that you can use Hyper-V and run a virtual 2008 server. I don't know if that's an option for you. It seems a bit extreme but it's just an idea. 

Re: SIM Alerts

0
0

Hello again,

 

Now that you've installed the SPP you need to tell your server where to send the SNMP or WBEM events to. That would be the SIM server. Depending on your OS it can be either  SNMP on Linux or older ESX servers or WBEM on windows servers.

 

For SNMP you need to configure SNMP  to send traps to the SIM server, for WBEM you need to set a WBEM subscription from SIM. If you need more info how to set these let me know.

Re: SNMP outbound broken after 7.2 upgrade

0
0

Currently I am running SQL Express as I am waiting for my DB team to help me move the DB into a proper SQL cluster.

 

Re: 1785 Drive Array Not Configurer - How to Not receive the alert on a server

0
0

Hi thanks

 

so .. it seems there is  no real solution ... 

This error message occour, when a smart array controller find no configuration on the drives.
You will allways get it on the very first boot.
Or if you have a unused array controller in the system, then you will get it on all boots.

Viewing all 4342 articles